AI for Studio 5000 and RSLogix 5000 projects
Altitude opens a Logix project the way Studio 5000 shows it, every rung drawn as ladder, then explains, reviews, changes and documents it, with each change checked against the whole project before it is written.
- Vendor
- Rockwell Automation
- Languages
- LadderStructured textFunction blockSFC
- Files
- .L5X.L5K
- Covers
- ControlLogixCompactLogixGuardLogixPlantPAxVersion 17 to the present
- 1 Save the project as .L5X or .L5K from Studio 5000
- 2 Review the changed rungs and record an approval if required
- 3 Import the selected export into Studio 5000. Your engineer handles the controller download there
Everything a Studio 5000 Logix file holds, in one conversation
Follow the cited source and review edits in the project copy. File History keeps the versions so your team can choose what to release.
- Explain a sequence, and trace any output back through the logic to the inputs holding it
- Troubleshoot a fault from its symptom, and review for defects ranked by severity, each with its rung, risk and fix
- Change ladder, structured text, function blocks, SFC, tags, data types, Add-On Instructions, modules, tasks, alarms and motion
- Comment thousands of rungs at once, rename with every reference following, and copy parts between projects
- Compare versions, plants and stations, and reconcile the I/O against the drawings or an I/O list
- Start a new project from a sequence of operations or an I/O list, and move a project onto a newer controller or version
- Mark every change to safety logic, safety tags, tasks and modules as Safety in its diff, for your safety engineer’s review
- Keep the .ACD beside its export, versioned and approved like any file
- Check against industrial standards such as IEC 61131-3, ISA-88, ISA-95 and PackML, or your own
Requests engineers type every day
- Why won’t the infeed conveyor restart after an e-stop reset?
- Add a Servos_Ready interlock to the gearing rung and comment it.
- Compare Line 3’s program with Line 4’s and list every difference.
The work Studio 5000 Logix projects need most
Read beside the rest of the line
RSLogix 500 Rockwell Automation SLC 500 and MicroLogix ladder, data files and descriptions, from the .SLC export and its .SY6. .SLC.SY6.SY5.EAS RSLogix 5 (PLC-5) Rockwell Automation PLC-5 ladder, data files and documentation, from the .PC5 export and its .CSV. .PC5.CSV.EAS TIA Portal Siemens S7-1200, S7-1500, S7-300 and S7-400 programs, from TIA Portal V14 to V21 exports. SimaticML.scl.awl.db STEP 7 Classic Siemens S7-300 and S7-400 block sources, symbols and hardware configuration from SIMATIC Manager. .awl.scl.sdf.seq
See Altitude on your Studio 5000 Logix files
We'll walk through the requests that matter to your team on the platforms you run, from review and troubleshooting to documents and migration.