AI for SEL RTAC projects in acSELerator RTAC
On a solar, wind or storage plant the RTAC is often both the plant controller and the gateway. Altitude reads its acSELerator RTAC XML export as acSELerator lays it out, from the curtailment logic to every DNP3 point SCADA polls, and checks and changes it.
- Vendor
- Schweitzer Engineering Laboratories
- Languages
- Structured textCFC
- Files
- acSELerator RTAC XML exportPoints lists (.xlsx, .csv)
- Covers
- SEL-3530SEL-3530-4SEL-3555SEL-3350SEL-3505SEL-3560Axion SEL-2241acSELerator RTAC (SEL-5033)
- 1 Export the project to XML in acSELerator RTAC, and add its folder to the project
- 2 Review each change, drawn as acSELerator lays it out, and record an approval if your team needs one
- 3 Import the folder into acSELerator RTAC as a new project, then build and send it to the RTAC
Everything a SEL RTAC file holds, in one conversation
Follow the cited source and review edits in the project copy. File History keeps the versions so your team can choose what to release.
- Explain the plant controller’s setpoint, ramp-rate and curtailment logic, and trace a tag through ST, CFC and the Tag Processor
- Read every DNP3, Modbus, GOOSE, C37.118 and SEL protocol map, point by point with its address
- Reconcile the point maps against a points list from the utility or SCADA integrator, and write the comparison as a spreadsheet
- Change logic, declarations, tasks and settings-grid cells, and add or remove DNP points, Modbus registers and Tag Processor rows
- Add Modbus, DNP3 and C37.118 devices from a library of devices and controllers, with their address and port
- Translate RTAC logic to Studio 5000, TIA Portal or TwinCAT 3, or start a new RTAC project from one of them
- Download any POU, GVL, device or tag list with everything it uses, as a part to import
- Check against industrial standards such as IEC 61131-3, ISA-88, ISA-95 and PackML, or your own
Requests engineers type every day
- Why does the plant ramp past 10% a minute when the POI meter drops out?
- Check the DNP3 server map against the utility’s points list and list every mismatch.
- Add a Modbus TCP inverter at 10.20.1.45 with the same tags as INV_01.
The work SEL RTAC projects need most
Read beside the rest of the line
Studio 5000 Logix Rockwell Automation ControlLogix, CompactLogix and GuardLogix projects, from .L5X and .L5K exports. .L5X.L5K RSLogix 500 Rockwell Automation SLC 500 and MicroLogix ladder, data files and descriptions, from the .SLC export and its .SY6. .SLC.SY6.SY5.EAS RSLogix 5 (PLC-5) Rockwell Automation PLC-5 ladder, data files and documentation, from the .PC5 export and its .CSV. .PC5.CSV.EAS TIA Portal Siemens S7-1200, S7-1500, S7-300 and S7-400 programs, from TIA Portal V14 to V21 exports. SimaticML.scl.awl.db
See Altitude on your SEL RTAC files
We'll walk through the requests that matter to your team on the platforms you run, from review and troubleshooting to documents and migration.